Storage between use
Observe the following for long-term storage of a pump station.
Insure system is drained of any water.
Remove transducers to ensure that they do not freeze.
System may be top-heavy, brace to keep from tipping.
Long-term storage
If the unit is stored for more than 6 months, these requirements apply:
Store in a covered and dry location.
Store the unit free from heat, dirt, and vibrations.
Rotate the pump shaft by hand several times at least every three months.
Treat bearings and machined surfaces so that they are well preserved. Refer to the drive
unit and coupling manufacturers for their long-term storage procedures.
For questions about possible long-term storage treatment services, please contact your
local sales and service representative.
Transportation and Storage
AquaForce Variable Speed Package System Mechanical Installation, Operation, and Maintenance Manual 9