Vista de pagina 0
Global Water
800-876-1172 globalw.com
- 1 -
Global Water
Instrumentation, Inc.
151 Graham Road
P.O. Box 9010
College Station, TX 77842-9010
T: 800-876-1172
Int’l: (979) 690-5560, Fax: (979) 690-0440
E-mail : globalw@globalw.com
PC320 Process Controller
02-107
Publication Number 39370712
Vista de pagina 0
1 2 3 4 5 6 ... 18 19

Indice de contenidos

Pagina 1 - Global Water

Global Water 800-876-1172 • globalw.com - 1 - Global Water Instrumentation, Inc.

Pagina 2

Global Water 800-876-1172 • globalw.com - 10 - Relay Modes: Off: In Off mode, relays will not turn on regardless of settings One Time: In One

Pagina 3

Global Water 800-876-1172 • globalw.com - 11 - VIII. Power Saving Mode A power saving mode is provided that allows the operating current to be re

Pagina 4

Global Water 800-876-1172 • globalw.com - 12 - button to enter any of the setup sub-menus. These sub-menus are Set Sensor Type, Calibrate Sensor,

Pagina 5 - II. PC320 Specifications:

Global Water 800-876-1172 • globalw.com - 13 - First select whether the sensor will be calibrated using a 2 or 3 point method. Generally; sensors

Pagina 6 - III. Display Modes

Global Water 800-876-1172 • globalw.com - 14 - identifiers for the user on the LCD display. Calibrate the sensor normally. You can set the senso

Pagina 7 - IV. Switch Settings

Global Water 800-876-1172 • globalw.com - 15 - SAVE and MENU. A sensor does not need to be connected during this process. The 20mA Output Cal me

Pagina 8 - V. Sensor Input

Global Water 800-876-1172 • globalw.com - 16 - SAVE to store the setting. The Sensor Warmup time is how long the sensor will be powered on before

Pagina 9

Global Water 800-876-1172 • globalw.com - 17 - Relay Test Mode: To manually test relay operation, press the RIGHT arrow. Use UP and DOWN to sel

Pagina 10

Global Water 800-876-1172 • globalw.com - 18 - Be prepared to describe the problem you are experiencing including specific details of the applicat

Pagina 11 - IX. Scientific Notation

Global Water 800-876-1172 • globalw.com - 19 - XIII. Appendix A: Terminal Strip Diagram POWER IN: V+ 12VDC or 18-24VDC Input V+

Pagina 12

Global Water 800-876-1172 • globalw.com - 2 - Congratulations on your purchase of the Global Water PC320 Process Controller. This instrument h

Pagina 13

Global Water 800-876-1172 • globalw.com - 3 - I. PC320 Process Controller Description The PC320 Process Controller is reliable, accurate and sui

Pagina 14

Global Water 800-876-1172 • globalw.com - 4 - Both normally open and normally closed relay contacts are provided. Relay modes include a One Time

Pagina 15

Global Water 800-876-1172 • globalw.com - 5 - II. PC320 Specifications: Power Requirements: 12VDC or 18-24VDC Input, +/-10% Supply Current:

Pagina 16

Global Water 800-876-1172 • globalw.com - 6 - III. Display Modes The PC320 has three display modes, pressing the DISPLAY button on the front pa

Pagina 17 - XII. Technical Support

Global Water 800-876-1172 • globalw.com - 7 - IV. Switch Settings Inside the PC320 is a bank of 8 switches which are used to select the sensor t

Pagina 18

Global Water 800-876-1172 • globalw.com - 8 - V. Sensor Input The PC320 accepts any analog sensor with a 4-20mA, 0-5VDC or 0-1VDC output. Avai

Pagina 19

Global Water 800-876-1172 • globalw.com - 9 - Since in normal use the water level will never fall below zero, the Lower Threshold will have no eff