Global Water
800-876-1172 globalw.com
IV. Specifications
Power: WL200 110 AC (220 AC Optional)
Sensing Heads:
Electrodes 24” length, standard
72” length, maximum (with two extensions)
May be cut to custom length
Materials 316 Stainless Steel electrodes
Polypropylene all food-grade materials
Mounting 1” NPT, standard
Bulkhead or snap-in flange optional
Pressure 30 PSIG, maximum
Temperature 100°C, maximum (212°F)
R-Series Controllers:
Sensing Inputs 3 maximum (High, Low, Common)
Output Contact rating 5 Amps resistive @ 240 VAC, form
SPDT
Sensing Type ON/OFF Resistance
Voltage at Probe 12 VAC nominal
Terminals
Sensing Resistance Factory-fixed or adjustable to 100,000 ohms
Sensing Resistance Factory-fixed – ±10%; adjustable – guaranteed
Tolerance range
Voltage 120 or 230 VAC
- 5 -